Main Pumps
3 × variable swash plate pumps
Main Pumps - Maximum Total Oil Flow
407 gpm
1544 L/min
Main Pumps - Maximum Pressure - Attachment
4641 psi
320 bar
Pilot Pump - Maximum Flow, Pilot
40.4 gpm
153 L/min
Pilot Pump - Maximum Pressure, Pilot
1378 psi
95 bar
Main Pumps - Maximum Pressure - Travel
4641 psi
320 bar
Engine Fan Pump - Maximum Flow, Engine Fan
53.1 gpm
201 L/min
Engine Fan Pump - Maximum Pressure, Engine Fan
3191 psi
220 bar
Swing Pump
1 × variable swash plate pump
Engine Fan Pump
1 × variable swash plate pump
Swing Pump - Maximum Flow - Swing
127 gpm
479 L/min
Hydraulic Fan Pump - Maximum Pressure, Hydraulic Fan
1958 psi
135 bar
Hydraulic Fan Pump - Maximum Flow, Hydraulic Fan
22.7 gpm
86 L/min
Hydraulic Fan Pump
1 × variable swash plate pump
Swing Pump - Maximum Pressure - Swing
5294 psi
365 bar
Hydraulic Oil Cooling - Maximum Flow
284 gpm
1075 L/min
Hydraulic Oil Cooling - Diameter of Fan
46 in
1168 mm
Filters (1)
Full-flow high-pressure filters (200 μm) for main pumps
Filters (2)
Full-flow filters (20 μm), return circuit
Filters (3)
Pressure filters (16 μm), servo circuit
Filters (4)
Full-flow filters (6 μm), cooling return circuit
Filters (5)
Swing charge filter (15 μm)
Filters (6)
Pump case return screens (125 μm)